Email: info@mcleanroom.com WhatsApp: +86 138 1493 2168
Home / Projects

Cleanroom Projects Delivered Worldwide

A selection of recent turnkey projects and equipment supplies. Client names are confidential, but every reference can be verified — ask us for a contact in your industry.

GMP Grade A/B Sterile Fill-Finish Suite — Pharmaceutical Client, Spain

480 m², ISO Class 5 / Grade A in Grade B background. EU GMP Annex 1 compliant, validated with full documentation. Design to handover in 14 weeks.

SMT Assembly Cleanroom — Electronics Manufacturer, United Arab Emirates

1,200 m², ISO Class 7 with ESD-safe surfaces. EC-motor FFU ceiling system, energy-optimized for high ambient temperatures. Turnkey construction plus operator training.

Dairy Processing Hygiene Zone — Food Producer, Egypt

800 m² washdown-rated processing and packaging areas. HACCP-flow layout, corrosion-resistant envelope. Passed first-round BRCGS audit with zero hygiene non-conformities.

Modular Operating Theatre Package — Hospital Group

4 operating theatres, ISO Class 5 laminar flow. Prefabricated modules shipped flat-packed, installed with local team supervision.

FFU & Filter Supply Program — Cleanroom Contractor, Germany

900+ FFU units with EC motors and group control. Two-year supply program; per-unit test reports for every shipment.

Project Story: GMP Grade A/B Sterile Fill-Finish Suite, Spain

Overview. A Spanish pharmaceutical manufacturer needed a new sterile fill-finish suite to launch a lyophilized injectable product line. The facility had to comply with the revised EU GMP Annex 1 and pass inspection by the national regulator on the first attempt.

Scope. Cleanroom design and CFD airflow simulation; magnesium rock-wool panels, flush doors and windows; Grade A laminar airflow zones with H14 terminal filtration; HVAC with pressure cascade control and BMS integration; commissioning, qualification (IQ/OQ/PQ) and certification.

Area480 m²
ClassificationISO 5 (Grade A) / ISO 7 (Grade B background)
Temperature / RH20 ± 2 °C / 45 ± 10 %
Timeline14 weeks from design approval to handover

Challenge & solution. The existing building had a low ceiling height that ruled out conventional ductwork above the Grade A zone. We solved this with a recirculating FFU ceiling system integrated into the panel ceiling — achieving unidirectional airflow without raising the roof.

Results. The suite passed regulatory inspection on the first attempt. Particle counts measured at 30–50% below ISO Class 5 limits at rest, giving the client comfortable operating margin.

"The documentation package was the most complete we have received from any supplier." — Project Director

Planning a Similar Project?

Talk to the engineers who delivered it. Free design proposal within 24 hours.

Talk to Our Engineers
WhatsApp Us